Accurate NH₃ slip measurement is essential to verifying SCR/SNCR performance and maintaining CARB compliance. REM delivers defensible, method-driven testing that gives clients clear, actionable insight into ammonia emissions.
Ammonia (NH₃) Slip Testing for CARB Compliance
As part of our CARB-compliant source testing services, REM Environmental incorporates ammonia (NH₃) slip measurement to support facilities operating selective catalytic reduction (SCR) or selective non-catalytic reduction (SNCR) systems. Monitoring NH₃ slip is critical for demonstrating proper system performance, optimizing reagent usage, and ensuring compliance with evolving regulatory requirements.
What is NH₃ Slip?
NH₃ slip refers to unreacted ammonia passing through the emissions control system and being released in the exhaust stream. While ammonia is injected to reduce NOₓ emissions, incomplete reaction or over-injection can result in measurable NH₃ emissions. Excessive slip can contribute to secondary particulate formation, visible plumes, odor issues, and potential regulatory exceedances.
REM’s Measurement Approach
REM utilizes proven, CARB-accepted source test methodologies to quantify ammonia emissions with high accuracy and repeatability. Our approach is tailored to the specific process and control technology but generally includes:
Isokinetic or extractive sampling techniques designed to capture representative flue gas conditions
Use of impinger trains or sorbent-based collection systems to selectively capture ammonia from the gas stream
Strict adherence to method-defined temperature control and moisture management to prevent ammonia loss or transformation during sampling
Field quality controls including calibration checks, blanks, and duplicate runs to ensure data integrity
Depending on project requirements, REM may apply methodologies aligned with:
Conditional Test Method (CTM-027 or equivalent) for ammonia
ASTM D6348 (FTIR-based analysis) for real-time or integrated measurement
Other CARB-approved or site-specific protocols
Analytical Process
Collected samples are analyzed using laboratory-based wet chemistry techniques or instrumental methods such as Fourier Transform Infrared Spectroscopy (FTIR). These methods allow for:
Quantification of ammonia concentration (ppmvd or lb/hr)
Correction to standard conditions (e.g., dry basis, reference oxygen content)
Cross-verification with process and control system operating parameters
Quality Assurance and Data Integrity
REM follows a rigorous QA/QC framework consistent with CARB and EPA expectations:
Pre- and post-test leak checks and calibration verification
Chain-of-custody documentation for all samples
Use of method blanks and spiked samples where applicable
Data validation to confirm method compliance and defensibility
Why NH₃ Slip Testing Matters
Accurate measurement of ammonia slip provides actionable insight into system performance:
Optimizes reagent injection rates, reducing operational costs
Prevents ammonium salt formation that can foul downstream equipment
Supports regulatory reporting and permit compliance
Demonstrates environmental stewardship and operational control